Generated power will increase decrease linearly during dusk and dawn and no power is produced at night.
Solar panel accumulator ratio.
500 21 p mw solar panels 20 p mw accumulators these are the numbers i use.
Now connectible to the circuit network.
Alternatively this works out to a ratio of 25 solar panels to 21 accumulators.
If your power draw is constant then the optimal ratio is 25 solar panels to 21 accumulators.
The optimal ratio is 0 84 21 25 accumulators per solar panel and 23 8 solar panels per megawatt required by your factory this ratio accounts for solar panels needed to charge the accumulators this means that you need 1 428 mw of production of solar panels and 100mj of storage to provide 1 mw of power over one day night cycle.
Then when both of those are met build some more.
If your batteries can t fully charge during the day build more solar.
Solar panels and accumulators optimal ratio.
If they don t last the night build more batteries.
Take the current ratio of 0 84 and multiply it by 100 60 5 10 which gets me 0 7.
Solar panels are an unlimited source of free energy that produce no pollution.
This means one solar panel produces an average of 42 kw over one day and night cycle.
I had found that a ratio of 1 2 to 1 5 accumulators per solar panel worked out perfectly fine.
Your solar panels have 2 functions.
100kw from 60 accumulator capacity.
In general this is a technique which works well when you ve just researched accumulators and solar panels but don t have enough resources to build big solar farms and accumulator farms yet.
Reduced collision box of big electric pole to allow squeezing between it and an accumulator.
Solar panels are producing 0 nominal power 10 of the day.
Dusk dawn so on average they produce 70 of nominal power.
Solar panel max output.
If there is variance than you need to know what the greatest possible drain over the timespan from beginning of dusk to end of dawn is i e.
I calculated it in two ways.
10 mj from 5 as far as i know the length of the day hasn t changed.
Night solar panels are producing 50 nominal power 40 of the day.
K2 changed the power output of panels and capacity of accumulators.
Entire timespan that solar panels are not producing 100 energy will be.
While the sun is out your solar panels have to output q power where q p.
The amount of solar panels and accumulators you need is more.
The ratio doesn t matter nearly as much as people seem to think it does.
Provide power p recharge accumulators.
So for 2 1mw this works out to 50 solar panels and 42 accumulators exactly.